How choose Two-pole Circuit Breaker and Wires
Models
S3-30A
S3-40A
S3-50A
S3-60A
Pure copper wires
6mm²/9AWG
6mm²/9AWG
2PCS 6mm²/9AWG
2PCS 6mm²/9AWG
Circuit Breaker
2PCS 63A
2PCS 63A
2PCS 63A
2PCS 100A
Warning
Be aware that only qualified professionals should install these controllers. Please read full
manual before installing. Please don’t set any parameters if you are not a professional
installer. The controller will work well on defaults for Lead acid. Lithium battery require
parameter change.
The controllers should be installed indoors only. Keep controller away from water. Don’t
use wet towel to wipe controller.
Never open the controller case without permission. Never reverse input PV polarity.
Never reverse the battery polarity. Never overpower input PV.
The controller can't connect 110V or 240V or any other AC appliances in the OUT+, OUT-
terminal. The output is only for DC load current less than 5A. If your battery is 48V, then
load should be 48V and current less than 5A.
Must use two-pole circuit breakers, and make sure the input and output are using
separate circuit breakers.
Use the pure copper wires and connect all polarity correctly.
Please don’t insert any meter or other devices between controller and battery or controller
and PV.
It’s important to open terminal lugs 100% before inserting wire into terminal block. Then
tighten and recheck to make sure wires are secure.
Please note that running maximum wattage could be a hazard if atmospheric conditions
allow for PV array to over power unit. There are times that a 2880 rated PV array can
produce in excess of 3400 watts. This can damage controller. It is best to allow room for
that occurance.
Please refer to an awg wire size calculator to properly size your wire from your PV, Battery,
and Inverter. When in doubt, larger size wire is always a better choice.