Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  96  2015-08-03 
whose duration is determined by <duration>. 
<duration> Duration of the tone in 1/10 seconds range :1-255 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
Number of DTMF characters*duration. 
Reference 
3GPP TS 27.007 
[13] 
Note 
3.2.38 AT+CMUX Multiplexer Control 
AT+CMUX Multiplexer Control 
Response 
+CMUX: (0) 
OK 
Test Command 
AT+CMUX=? 
Parameters 
See Write Command 
Response: 
+CMUX:[<mode>[,<subset>[,<port_speed>[,<N1>[,<T1>[,<N2>[,<T2
>[,<T3>[,<k>]]]]]]]]] 
OK 
ERROR 
Read Command 
AT+CMUX? 
Parameters 
<mode>  Multiplexer transparency mechanism 
0 Basic option 
<subset> The way in which the multiplexer control channel is set up 
0 UIH frames used only 
<port_speed> Transmission rate 
  1 9600 bits/t 
  2 19200 bits/t 
  3 38400 bits/t 
  4 57600 bits/t 
5 115200 bit/s 
  6 230400 bits/t 
  7 460800 bits/t 
  Proprietary values, available if MUX NEW PORT 
SPEED FTR is activated 
<N1> Maximum frame size 
1-255 Default: 127 
<T1> Acknowledgement timer in units of ten milliseconds 
1-255 Default:10 (100 ms) 