Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  93  2015-08-03 
Response 
+CRSM: <sw1>, <sw2>[,<response>] 
OK 
ERROR 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+CRSM=<Co
mmand>[,<fileId
>[,<P1>,<P2>,<P
3>[,<data>]]] 
Parameters 
<Command> 
176 READ BINARY 
178 READ RECORD 
192 GET RESPONSE 
214 UPDATE BINARY 
220 UPDATE RECORD 
242 STATUS 
All other values are reserved; refer GSM 11.11. 
<fileId> Integer type; this is the identifier for an elementary data file on 
SIM. Mandatory for every Command except STATUS 
<P1>,<P2>,<P3> Integer type, range 0 – 255 
Parameters to be passed on by the ME to the SIM; refer GSM 
11.11. 
<data> Information which shall be written to the SIM (hex-decimal 
character format) 
<sw1>, <sw2> Integer type, range 0 - 255 
Status information from the SIM about the execution of the 
actual Command. These parameters are delivered to the TE in 
both cases, on successful or failed execution of the Command; 
refer GSM 11.11. 
<response> Response of a successful completion of the Command 
previously issued (hexadecimal character format) 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
3GPP TS 27.007 
GSM 11.11 
Note 
3.2.35 AT+CSQ Signal Quality Report 
AT+CSQ Signal Quality Report 
Test Command 
AT+CSQ=? 
Response 