Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  81  2015-08-03 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Parameters 
<stat> 0  Unknown 
 1  Operator available 
 2  Operator current 
  3 Operator forbidden  
<oper> 
Refer to [27.007]
operator in format as per <format> 
<mode>  0 Automatic mode; <oper> field is ignored 
 1 Manual (<oper> field shall be present, and <AcT> 
optionally) 
  2 manual deregister from network 
  3 set only <format> (for read Command +COPS?) - not 
shown in Read Command response 
4  Manual/automatic (<oper> field shall be present); if 
  manual selection fails, automatic mode (<mode>=0) is 
entered 
<format> 0 Long format alphanumeric <oper> 
  1 Short format alphanumeric <oper> 
  2 Numeric <oper>; GSM Location Area Identification 
number 
Parameter Saving 
Mode 
AUTO_SAVE 
Max Response 
Time 
Test command: 45 seconds 
Write command: 120 seconds 
Reference 
3GPP TS 27.007 
[14] 
Note 
3.2.23 AT+CPAS Phone Activity Status 
AT+CPAS Phone Activity Status 
Response 
+CPAS: (list of supported <pas>s) 
OK 
Test Command 
AT+CPAS=? 
Parameters 
See Execution Command 
Execution 
Command 
AT+CPAS 
Response 
TA returns the activity status of ME. 
+CPAS: <pas> 