SIM800 Series_AT Command Manual_V1.09  53  2015-08-03 
   3 space (0) 
Parameter Saving 
Mode 
AT&W_SAVE 
Max Response 
Time 
- 
Reference 
V.25ter 
Note 
The Command is applied for Command state; 
In <format> parameter, "0 parity" means no parity; 
The <parity> field is ignored if the <format> field specifies no parity and 
string "+ICF: <format>,255" will be response to AT+ICF? Command. 
2.2.40 AT+IFC Set TE-TA Local Data Flow Contro
l 
AT+IFC Set TE-TA Local Data Flow Control 
Response 
+IFC: (list of supported <dce_by_dte>s),(list of supported 
<dte_by_dce>s) 
OK 
Test Command 
AT+IFC=? 
Parameters 
See Write Command 
Response 
+IFC: <dce_by_dte>,<dte_by_dce> 
OK 
Read Command 
AT+IFC? 
Parameters 
See Write Command 
Response 
This parameter setting determines the data flow control on the serial 
interface for data mode. 
OK 
Write Command 
AT+IFC=<dce_b
y_dte>[,<dte_by
_dce>] 
Parameters 
<dce_by_dte> Specifies the method will be used by TE at receive of 
data from TA 
     0 No flow control 
      1 Software flow control 
2 Hardware flow control 
<dte_by_dce> Specifies the method will be used by TA at receive of data 
from TE 
     0 No flow control 
      1 Software flow control 
      2 Hardware flow control 