SIM800 Series_AT Command Manual_V1.09  37  2015-08-03 
To prevent the +++ escape sequence from being misinterpreted as data, it 
should comply to following sequence: 
No characters entered for T1 time (1 second) 
"+++" characters entered with no characters in between (1 second) 
No characters entered for T1 timer (1 second) 
Switch to Command mode, otherwise go to step 1. 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
V.25ter 
Note 
To return from Command mode back to data mode: Enter ATO. 
2.2.13 ATO    Switch from Command Mode to Data Mode 
ATO Switch from Command Mode to Data Mode 
Response 
TA resumes the connection and switches back from Command mode to data 
mode. 
CONNECT 
If connection is not successfully resumed 
ERROR 
else 
TA returns to data mode from command mode CONNECT <text>  
Note: <text> only if parameter setting ATX>0 
Execution 
Command 
ATO[n] 
Parameter 
<n> 0 Switch from command mode to data mode. 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
V.25ter 
Note 
2.2.14 ATP Select Pulse Dialling 
ATP Select Pulse Dialling 
Execution 
Command 
ATP 
Response 
OK 