The peak throughput class 
The mean throughput class 
And is decided in "requested QOS” and "minimum acceptable QOS”. 
All parameters of the QOS are initiated by default value (=0) except the reliability class is 3. To 
define a QOS use the AT+CGQREQ or AT+CGQMIN Command. 
Overwrite the precedence class of 
QOS of CID 1 and sets the QOS of 
CID 1 to be present 
AT+CGQREQ=1,0,0,3
,0,0 
OK 
Response: all QOS values of the 
activated CID. 
AT+CGQREQ?  +CGQREQ: 1,0,0,3,0,0 
+CGQREQ: 2,0,0,3,0,0 
+CGQREQ: 3,0,0,3,0,0 
OK 
Set the QOS of CID 1 to not present. 
Once defined, the CID can be activated. 
AT+CGQREQ=1  OK 
Activate CID 1, if the CID is already 
active, the mobile returns OK at once. 
If no CID is defined the mobile responds 
+CME ERROR: invalid index. 
Note: If the mobile is NOT attached 
by AT+CGATT=1 before activating, the 
attachment is automatically done by the 
AT+CGACT Command. 
AT+CGACT=1,1 
AT+CGACT=1,3 
OK 
+CME ERROR: requested 
service option not 
subscribed. 
Use the defined and activated CID 
to get online. The mobile can be 
connected using the parameters of 
appointed CID or using default 
parameter 
AT+CGDATA="PPP", 
1 
CONNECT 
The mobile supports Layer 2 Protocol (L2P) PPP only. 
Note: If the mobile is NOT attached by AT+CGATT=1 and the CID is NOT activated before 
connecting, attaching and activating is automatically done by the AT+CGDATA Command. 
Some providers require using an APN to establish a GPRS connection. So if user uses the 
Microsoft Windows Dial-Up Network and ATD*9… to connect to GPRS, user must provide the 
context definition as part of the modem definition (Modem properties/Connection/Advanced… 
/Extra settings.) As an alternative, user can define and activate the context in a terminal program 
(e.g. Microsoft HyperTerminal) and then use the Dial-Up Network to send only the ATD 
Command. 
20.9 TCPIP Commands 
Please refer to SIM800 Series_TCPIP_Application Note.doc 