Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  30  2015-08-03 
If connection successful and voice call 
OK 
Parameters 
<n>    String of dialing digits and optionally V.25ter modifiers dialing 
digits: 0-9, * , #, +, A, B, C 
 Following V.25ter modifiers are ignored: 
 ,(comma), T, P, !, W, @ 
Emergency call: 
<n> Standardized emergency number 112 (no SIM needed) 
<mgsm> String of GSM modifiers: 
  I Actives CLIR (Disables presentation of own number to 
called party) 
  i Deactivates CLIR (Enable presentation of own number 
to called party) 
  G  Activates Closed User Group invocation for this call 
only 
   g  Deactivates Closed User Group invocation for this call 
only 
<;>  Only required to set up voice call , return to Command state 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
20s(voice call) 
Timeout set with ATS7 (data call) 
Reference 
V.25ter 
Note 
Parameter "I" and "i" only if no *# code is within the dial string 
<n> is default for last number that can be dialed by ATDL 
*# codes sent with ATD are treated as voice calls. Therefore, the Command 
must be terminated with a semicolon ";" 
See ATX Command for setting result code and call monitoring parameters.
Responses returned after dialing with ATD 
For voice call two different responses mode can be determined. TA returns 
"OK" immediately either after dialing was completed or after the call is 
established. The setting is controlled by AT+COLP. Factory default is 
AT+COLP=0, this cause the TA returns "OK" immediately after dialing 
was completed, otherwise TA will returns "OK", "BUSY", "NO DIAL 
TONE", "NO CARRIER". 
Using ATD during an active voice call: 
When a user originates a second voice call while there is already an active 
voice call, the first call will be automatically put on hold. 