Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  212  2015-08-03 
Response 
+CGQREQ:  <PDP_type>,(list of supported <precedence>s),(list of 
supported <delay>s),(list of supported <reliability>s),<list of supported
<peak>s),(list of supported <mean>s) 
[<CR><LF>+CGQREQ: <PDP_type>,(list of supported <precedence> 
s),(list of supported <delay>s),(list of supported <reliability>s),(list of 
supported <peak>s),(list of supported <mean>s) 
[…]] 
OK 
Test Command 
AT+CGQREQ=? 
Parameters 
See Write Command 
Response 
+CGQREQ: <cid>,<precedence>,<delay>,>reliability>,<peak>,<mean>
[<CR><LF>+CGQREQ: 
<cid>,<precedence>,<delay>,<reliability>,<peak>,<mean> 
[…]] 
OK 
Read Command 
AT+CGQREQ? 
Parameters 
See Write Command 
Response 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+CGQREQ=c
id>[,<precedence
>[,<delay>[,<reli
ability>[,<peak>[
,<mean>]]]]] 
Parameters 
<cid> A numeric parameter which specifies a particular PDP 
context definition (see +CGDCONT Command)  
The following parameter are defined in GSM 03.60 
<precedence> A numeric parameter which specifies the precedence class
0  QOS precedence class subscribed value 
1..3  QOS precedence class 
<delay> A numeric parameter which specifies the delay class 
0  QOS delay class subscribed value 
1..4 QOS delay class 
<reliability> A numeric parameter which specifies the reliability class 
0 QOS reliability class subscribed value 
1..5 QOS reliability class; default value: 3 
<peak> A numeric parameter which specifies the peak throughput 
class 
0  QOS peak throughput class subscribed value 
1..9  QOS peak throughput class 