Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  160  2015-08-03 
channel. Channel 2, 3 is virtual channel. 
6.2.20 AT+CSCLK Configure Slow Clock 
AT+CSCLK Configure Slow Clock 
Response 
+CSCLK: (list of supported <n>s) 
OK 
Test Command 
AT+CSCLK=? 
Parameter 
See Write Command 
Response 
+CSCLK: <n> 
OK 
Read Command 
AT+CSCLK? 
Parameter 
See Write Command 
Response 
OK 
ERROR 
Write Command 
AT+CSCLK=<n
> 
Parameter 
<n> 0 Disable slow clock, module will not enter sleep mode. 
1 Enable slow clock, it is controlled by DTR. When DTR is 
high, module can enter sleep mode. When DTR changes to low 
level, module can quit sleep mode. 
2 Enable slow clock automatically. When there is no interrupt 
(on air and hardware such as GPIO interrupt or data in serial 
port), module can enter sleep mode. Otherwise, it will quit sleep 
mode. 
Parameter Saving 
Mode 
AT&W_SAVE 
Max Response 
Time 
- 
Reference Note 
  There are two caveats when you want to quit sleep mode in mode 2: 
1, You should input some characters (at least one) to awake module 
2, An interval time of 100ms more is necessary between waking characters 
and following AT commands,otherwise the waking characters will not be 
discarded completely,and messy codes will be produced which may leads to 
UART baudrate re-adaptation. 
  The +CSCLK value can not be reset by AT&F or ATZ command. 