Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  129  2015-08-03 
If error is related to ME functionality: 
+CMS ERROR <err> 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
5s 
Reference 
3GPP TS 27.005 
Note 
4.2.12 AT+CSCA SMS Service Center Address 
AT+CSCA SMS Service Center Address 
Test Command 
AT+CSCA=? 
Response 
OK 
Response 
+CSCA: <sca>,<tosca>[,<scaAlpha>] 
OK 
Read Command 
AT+CSCA? 
Parameters 
See Write Command 
Response 
TA updates the SMSC address, through which mobile originated SMS are 
transmitted. In text mode, setting is used by send and writes commands. In 
PDU mode, setting is used by the same commands, but only when the 
length of the SMSC address coded into <pdu> parameter equals zero. 
Note: The Command writes the parameters in NON-VOLATILE memory. 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+CSCA=<sca
>[,<tosca>] 
Parameters 
<sca>   GSM 04.11 RP SC address Address-Value field in string 
format(string should be included in quotation marks); BCD numbers (or 
GSM default alphabet characters) are converted to characters of the 
currently selected TE character set (specified by +CSCS in 3GPP TS 
27.007); type of address given by <tosca> 
<tosca>   Service center address format GSM 04.11 RP SC address 
Type-of-Address octet in integer format (default refer <toda>) 
<scaAlpha>  String type(string should be included in quotation 
marks) 
 Service center address alpha data 
Parameter Saving NO_SAVE 