Manual
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  101  2015-08-03 
AT+CFUN=1,1 can be used to reset module purposely at minimum/full 
functionality mode.   
Response string "OK" will be returned after module resets if baud rate is 
set to fixed baud rate. 
3.2.43 AT+CCLK Clock 
AT+CCLK Clock 
Test Command 
AT+CCLK=? 
Response 
OK 
Response 
+CCLK: <time> 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Read Command 
AT+CCLK? 
Parameters 
See Write Command 
Response 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+CCLK=<tim
e> 
Parameters 
<time> String type(string should be included in quotation marks) 
value; format is "yy/MM/dd,hh:mm:ss±zz", where characters indicate 
year (two last digits),month, day, hour, minutes, seconds and time zone 
(indicates the difference, expressed in quarters of an hour, between the 
local time and GMT; range -47...+48). E.g. 6th of May 2010, 00:01:52 
GMT+2 hours equals to "10/05/06,00:01:52+08". 
Parameter Saving 
Mode 
AUTO_SAVE 
Max Response 
Time 
- 
Reference 
3GPP TS 27.007 
[13] 
Note 
Only time zone is auto saved. 
3.2.44 AT+CSIM Generic SIM Access 
AT+CSIM Generic SIM Access 
Test Command 
AT+CSIM=? 
Response 
OK 