User manual

1
3
13
2
4
6
8
5
7
9
10
11
12
14 15
MATHS Channel 1 (Cont’d)
8. Both CV Input: Bi-Polar Exponential control signal input for entire function. Contrary to the Rise and Fall CV Inputs, BOTH has an
Exponential response and Positive control signals decrease total time while Negative control signals increase
total time. Range +/-8V
9. Fall CV Input: Linear control signal input for Fall parameter. Positive control signals increase Fall time, Negative control signals
decrease Fall Time with respect to the Fall panel control. Range +/-8V
10. Cycle Input: On Gate HIGH, Cycles on. On Gate LOW, MATHS does not Cycle (unless the Cycle button is engaged).
Requires minimum +2.5V for HIGH.
11. Vari-Response Panel Control: Sets the response curve of the voltage function. Response is continuously-variable from
Logarithmic through Linear to Exponential to Hyper-Exponential. The Tick mark shows the Linear setting.
12. End Of Rise Output (EOR): Goes high at the end of the Rise portion of the function. 0V or 10V.
13. EOR LED: Indicates the states of the EOR Output. Lights when EOR is HIGH.
14. Unity Signal Output: signal from the Channel 1 circuit. 0-8V when Cycling. Otherwise, this output follows the
amplitude of the input.
15. Unity LED: indicates activity within the circuit. Positive voltages Green, Negative voltages Red.
7