INSTRUCTION MANUAL MT500 ANALOGUE INSULATION TESTER
Contents Page no 1. Safety Information ............................................................................4 2. Safety Symbols .................................................................................4 3. Specifications ...................................................................................4 3.1. General Information ................................................................4 3.2. Electrical Specifications ............................................................4 4.
1. SAFETY INFORMATION • Read the following safety information carefully before attempting to operate or service the meter. • To avoid damages to the instrument do not apply the signals which exceed the maximum limits shown in the technical specifications tables. • Do not use the meter or test leads if they look damaged. Use extreme caution when working around bare conductors or bus bars. • Accidental contact with the conductor could result in electric shock.
Range Function Display Measurement Range Large Analogue display 3Ω, 500Ω, 100MΩ/250V, 200MΩ/500V,400MΩ/1000V, 600V/ACV Operating Temperature 0ºC to 40ºC (32ºF to 104ºF) and Humidity below 80% RH Storage Temperature -10ºC to 60ºC (14ºF to 140ºF) and Humidity below 70% RH Power source DC9V (6x1.5V Size "AA" battery or Equivalent) Dimensions 200(L) x 92(W) x 50(H) mm Weight Approx 700g including battery Accessories Test leads, 6pcs battery, Carrying case, manual. 3.2.
4. PARTS & CONTROLS 1. Point needle 6. 2. Lock Button 7. 3. 0-Adjust Button 8. 4. Backlight Button 9. 5. Test Button. 10. Rotary Function switch VΩ Jack COM input jack Pothook Battery Cover 5. HOW TO CONNECT TEST LEADS. a) On MΩ Range: Connect the red test lead into the “VΩ” terminal and the black lead into the “COM” terminal. b) On3Ω/500Ω and ACV Range: Connect the red test lead into the “VΩ” terminal and the black lead into terminal “COM” 6. INSULATION RESISTANCE MEASUREMENTS 6.1.
the insulation will be high, and it will take longer for it to become charged by the direct testing voltage. Care must be taken not to take a reading until there is a steady reading, indicating that the charging process is complete. Note: The charge stored in the insulation will be discharged automatically when the test button is released. Be careful not to turn the range switch knob whilst the test button is pressed, or the instrument will be damaged. 6.2.