User Manual
7
27D7300
VWF Series Vented Gas Log Set
INSTALLATION
INSTALL AND OPERATE THE APPLIANCE AS DIRECTED IN THIS
MANUAL.
DAMPER STOP INSTALLATION
A damper stop must be provided with the unit. The damper stop must be installed as shown
in Figure 4 to prevent full closure of the replace damper blade and provide a minimum ue
opening, per table on page 5.
Should the clamp not t, or provide the required permanent opening from the table, have the
damper cut to provide a minimum permanent opening or install a permanent stop.
FOR MASSACHUSETTS RESIDENTS ONLY: Instal-
lation of this vented gas log in the Commonwealth of
Massachusetts requires the damper be permanently
removed or welded in the full open position. In addi-
tion, a naturally vented gas log may not be installed
in a bedroom or bathroom in the Commonwealth of
Massachusetts.
FP2727
damper
Damper Stop
Damper
FP2727
In compliance with ANSI Z21.60•CGA2.26 and National Fuel Gas Code, Section 6.
BEFORE INSTALLING THE APPLIANCE
• Turn off gas supply to replace or rebox.
• Clean replace oor and chimney before installing log set. Seal any ash. Clean out doors to
protect the unit from down drafts.
ASSEMBLY PROCEDURE
1. Place grate/burner assembly into rebox with the front pan facing forward.
2. Drill two (2) 5/32" diameter holes approximately 1Z\x" deep.
3. Anchor the front pan to the oor using the
screws provided.
Proper installation of the grate is essential to
prevent any movement of the gas logs and
controls during operation.
FP2728
secure burner assy
Screws
Injector
(Natural Gas Only)
FP2728