User Manual
27D7300
6
VWF Series Vented Gas Log Set
X
FP2726
restriction depth
PLACEMENT IN A FIREPLACE WITH A RESTRICTIVE BARRIER
IMPORTANT INFORMATION FOR THE INSTALLATION OF THIS GAS LOG
SET
The following are guidelines for placing a VWF log set with SPK, MVVK, or CVTHL kit in a replace
that has a restrictive barrier along the bottom front opening of the replace. Some examples of bar-
riers are glass/screen door frames and sunken/recessed replaces.
Glass door frames with
adjustable louvers should
have the lovers fully open
while the unit is in operation.
Height of restrictive barrier caused
by glass door frames, recessed
replaces, etc. from the base or
bottom surface of the unit. (See Table).
The log set should be placed against
or as near as possible to the rear wall
of the replace/rebox.
Depth of replace/rebox.
(Refer to Table).
NOTE: Noncombustible material such as refractory brick
may be used to line the oor of the replace in order to
raise the height of the gas log set in relation to a restrictive
barrier.
Height of Restriction (X) Minimum Depth of Fireplace/Firebox
No Restriction 13" - SPK (Manual Control)
13Z\x" - MVVK (Millivolt Control) and MXVK (Hi/Lo Control)
0 to 1Z\x" 15"
Greater than 1Z\x" to 3" 15"
Greater than 3" Any barrier greater than three inches (3") placed in front of the
gas log set is not recommended by the manufacturer
WARNING
Barriers such as the bottom of a glass door
frame placed in front of a gas log set can
change the air ow characteristics of the
replace which in turn can cause the unit
to overheat and malfunction. Any deviation
from the installation guidelines on this sheet
will potentially void the warranty.
CAUTION
If the replace has a restrictive barrier and
is equipped with a remote receiver, it must
be placed outside.