VWF Series Vented Gas Log Set
REMOTE CONTROL RECEIVER REPLACE-
MENT
The remote control receiver and batteries are very sensi-
tive to heat. Exposure to high temperatures can cause the
receiver to malfunction and shorten the life of the batteries.
If your replace does NOT have a restrictive barrier (Page
6), such as glass doors, it is recommended that the remote
receiver be afxed to the right hand side of the heat shield
or placed in the front, right corner of the replace. If your
replace has a restrictive barrier, it is recommended that
the remote receiver be placed outside of the replace.
The log set should be cleaned at least once a year for
maximum performance.
Turn gas supply off. Allow unit to cool. Remove logs,
handling carefully by holding gently at each end. Gloves
are recommended when handling the log to prevent skin
irritation from ceramic bers. If skin becomes irritated, wash
gently with soap and water. Refer to manual for correct log
placement. Brush each log gently with a soft bristle brush.
This will remove soot that has built up on the log set. DO
NOT USE LIQUID SOOT REMOVER ON LOGS!
CLEANING AND SERVICING
WARNING
Turn off gas logs and allow to cool before
cleaning. Disconnect electrical power if
applicable before cleaning or servicing.
LG911
clean log
To refurbish the grate, remove grate and take it outside.
Use a wire brush or sandpaper to remove any discoloration
to the grate. Paint grate with high temperature black paint
(barbecue paint). Reinstall grate after paint dries.
If embers (rock wool) have turned a rust color and become
brittle, remove old embers (rock wool) from log set. Replace
with new rock wool. Rock wool can be purchased from you
local dealer. See log placement section for placement of
embers.