User Manual

27D7300
48
VWF Series Vented Gas Log Set
LG909
VWF30 Flame appearance
FLAME APPEARANCE
CHECKING BURNER FLAMES
Flame should be yellow and extend vertically (not curling
toward replace screen).
PILOT FLAME APPEARANCE
The pilot ame must always be present when appliance is
operating. It should just touch the top of the thermocouple/
thermopile tip.


Ember bed should have
a yellow/orange glow
During manufacturing, fabricating, and shipping, various components of this appliance are treated
with certain oils, lms, or bonding agents. These chemicals are not harmful, but may produce annoy-
ing smoke and smells as they burn off the rst time the appliance is used. Operate the appliance
2 to 3 hours at the highest setting to burn off all the oils, lms, etc. Never use this appliance with
glassed doors closed. This could cause the pilot to go out and severe sooting outside the replace.
Always operate this appliance with the replace screens in place.
LG909


Thermocouple/
Thermopile Tip
LG910
SPK Pilot flame
LG910