User Manual

27D7300
46
VWF Series Vented Gas Log Set
OPERATING INSTRUCTIONS FOR MVVK KITS
1. Turn control knob clockwise to OFF position to completely shut off the heater.
2. If applicable: Turn ON/OFF switch to OFF position.
MILLIVOLT CONTROL LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. Turn gas control knob clockwise to the “OFF” position, and turn ON/OFF switch to “OFF” position.
4. Wait (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell
gas, STOP!
5. From
“OFF”
position, turn the gas control knob counterclockwise to “PILOT” position. Push
in control knob for 5 seconds.
6. With the control knob pushed in, light pilot with match.
7. Continue pushing the control knob in for a further 60 seconds to prevent the ame detector from
shutting off the gas while the probe is warming up. Release the control knob.
8. Turn gas control knob counterclockwise to the “ON” position.
9. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch
to “ON” position.
10. If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater and call your
service technician or gas supplier.



NOTICE
The Millivolt control does not come preassembled with an on/off switch so that
it may be customized for the specic application with a wall switch, remote, etc.
A switch/remote must be connected to enable the burner to light.
ON
OFF
P
I
I
L
O
T
LG908
on off switch
TO TURN OFF GAS TO HEATER