User Manual
13
27D7300
VWF Series Vented Gas Log Set
CONNECT THE GAS
NOTICE
NOTICE: A qualied gas appliance installer
must connect the appliance to the gas
supply. Consult all local codes before instal-
lation.
CAUTION
Use new black iron pipe, steel pipe, copper tubing, or internally tinned copper tubing.
Copper or internally tinned copper tubing can only according to the National Fuel
Gas Code, section 2.6.3, providing gas meets sulde limits, and where permitted by
local codes. Gas piping system must be sized to provide minimum inlet pressure
at the maximum ow rate (BTU/Hr). Undue pressure loss will occur if the pipe is
too small.
A manual shutoff valve must be installed upstream of the appliance. Union tee
and plugged 1/8" NPT pressure tapping point should be installed upstream of the
appliance.
WARNING
Connecting directly to an unregulated propane/
LPG tank can cause an explosion.
FP2739
gas connection
Pipe Coupling
To Gas Log Set or
to Gas Valve
Shutoff
Valve
Gas Supply Inlet
Pipe
IMPORTANT:Hold appliance rmly with a wrench to pre-
vent movement when connecting to inlet piping.
Always use an external regulator for all propane/LPG
gas logs only, to reduce the supply tank pressure to a
maximum of 13" w.c.
Locations that the Pressure
Tapping Point May be Installed