Vented Gas Log Set Models: VWF18NA, VWF24NA, VWF30NA, VWF36NA WARNINGS If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS 277300 VWF log cover Installation and Operating Instructions • Do not try to light any appliance.
VWF Series Vented Gas Log Set CONTENTS Thank you and congratulations on your purchase of a Vermont Castings Group Log Set. PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Important Safety Information .....................................3 Product Specifications ........................
IMPORTANT SAFETY INFORMATION OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. WARNING Read these instructions carefully before installing or trying to operate this vent-free gas heater. This product must be installed by a licensed plumber of gas fitter when installed within the Commonwealth of Massachusetts. • Any change to this heater or its controls can be dangerous.
safety information & Product specifications WARNING VWF Series Vented Gas Log Set Never connect unit to private (nonutility) gas wells. This gas is commonly known as wellhead gas. D A Nous recommandons que nos appareils de chauffage au gaz soient installés et entretenus par des professionnels qui ont été accrédités aux È.U. par le National Fireplace Institute ® (NFI) comme étant des spécialistes du NFI en matièred’appareils de chauffageC au gaz.
GETTING STARTED Check your packing list to verify that all listed parts have been received.
VWF Series Vented Gas Log Set Placement in a fireplace with a restrictive barrier Important information for the installation of this gas log set The following are guidelines for placing a VWF log set with SPK, MVVK, or CVTHL kit in a fireplace that has a restrictive barrier along the bottom front opening of the fireplace. Some examples of barriers are glass/screen door frames and sunken/recessed fireplaces. Height of Restriction (X) No Restriction 0 to 1Z\x" Greater than 1Z\x" to 3" Greater than 3"
INSTALLATION VWF Series Vented Gas Log Set Install and operate the appliance as directed in this manual. Damper stop installation A damper stop must be provided with the unit. The damper stop must be installed as shown in Figure 4 to prevent full closure of the fireplace damper blade and provide a minimum flue opening, per table on page 5.
INSTALLATION for gas valve kits Supplemental instructions for spkngA/spk-lpA WARNING VWF Series Vented Gas Log Set LP sets must be installed with a SPK or MVVKLP Kit which includes the air mixing nut and vermiculite. The natural gas orifice must be removed.
INSTALLATION for gas valve kits VWF Series Vented Gas Log Set Screw Figure 8 Install Pilot FP2731 FP2731 Install pilot Heat Shield FP2732 Figure 9 Install Heat Shield Gas Control Valve Knob Extensions Control Knob FP2732 install heat shield 27D7300
INSTALLATION for gas valve kits VWF Series Vented Gas Log Set WARNING supplemental instructionS for manvk Injector FP2733 Reducer Control Knob Valve The MANVK kit is for Natural Gas Only MANVK Kit Includes Valve Knob Extenders Control Knob Knob Extenders Figure 10 MANVK supplemental instructions for MVVKLPA MVVKLPA Kit FP2733 Includes MANVK Heat Shield Valve Assembly Pilot Heat Shield Air Mixing Injector Vermiculite Brass Nut supplemental instructions for MVVKNA MVVKNA Kit Includes Valve Ass
INSTALLATION for gas valve kits VWF Series Vented Gas Log Set supplemental instructionS for CVTHL-NG Heat Shield CVTHL-NG Kit Includes Valve Pilot for NG Pipe Nipple Knob Extender Heat Shield Self Tapping Screws Pilot Bracket Burner Fitting Pipe Nipple Natural Gas Injector Reducer Control Knob Gas Control Valve FP2736 Figure 13 CVTHL-NG Connecting Valve to Unit (Natural Gas only) FP2736 CVTHL ng Heat Shield CVTHL-LP Kit Includes Brass Nut Valve Pilot for LP Brass Nut Vermiculite LP Air-Mixing
WIRING - Millivolt Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing WARNING WARNING VWF Series Vented Gas Log Set Do not connect to 110 Volt supply THTP Millivolt Valve Pilot TP FP2738 TH Figure 15 Wiring Diagram Checking System Operation The Millivolt system and individual components may be checked with a Millivolt meter having a 0-1000MV range.
CAUTION VWF Series Vented Gas Log Set NOTICE: A qualified gas appliance installer must connect the appliance to the gas supply. Consult all local codes before installation. WARNING NOTICE CONNECT THE GAS Connecting directly to an unregulated propane/ LPG tank can cause an explosion. Use new black iron pipe, steel pipe, copper tubing, or internally tinned copper tubing. Copper or internally tinned copper tubing can only according to the National Fuel Gas Code, section 2.6.
log placement VWF Series Vented Gas Log Set filling THE burner pan Fill the burner pan with vermiculite to the bottom of the rear log and sloped to the front edge of the burner pan. Excess vermiculite can spill forward or to the side of the burner pan. Do not overfill the propane model. Do not cover the pilot (if SPK or MVVK is installed) with vermiculite or rock wool (embers).
log placement VWF Series Vented Gas Log Set 3. Place front left log #2 on the front of the grate and to the left. Figure 19 4. Place front right log #3 on the front of the grate and to the right. Figure 19 NOTE: Allow 2" between the back log and the two front logs. Front Right Log #3 Front Left Log #2 LG839 Figure 19 Place Front Left and Right Logs on Grate Left Side Middle Log #4 Right Side Middle Log #5 LG839 VWF18MO front logs 5. Place left side middle log #4 as shown. Figure 20 6.
log placement VWF Series Vented Gas Log Set VWF24 massive oak logs Shield Plate 1. Slide shield plate behind burner pan. Figure 22 2. Center rear log #1 on grate bars and flush with rear of the grate. Figure 23 Rear Log #1 Burner Pan Figure 22 Slide Shield Plate Behind Burner Pan LG830 VWF24 shield Front Left Log #2 Figure 23 Center Rear Log on Grate Bars LG842 LG830 Front Right Log #3 3. Place front left log #2 on the front of the grate and to the left. Figure 24 LG842 4.
log placement Left Side Middle Log #4 VWF Series Vented Gas Log Set Right Side Middle Log #5 6. Place right side middle log #5 as shown. Figure 26 7. Place left top log #7 as shown. Figure 26 Right Top Log #6 Figure 26 Place Right Side Middle Log and Left Top Log LG844 LG844 VWF24MO middle logs 8. Place right top log #6 as shown. Figure 27 Figure 27 Place Right Top Log VWF30 massive oak logs LG845 1. Slide shield plate down back of burner pan. Figure 28 LG845 VWF24MO top log Shield Plate 2.
log placement VWF Series Vented Gas Log Set Front Left Log #2 Front Right Log #3 3. Place front left log #2 on the front of the grate and to the left. Figure 30 4. Place front right log #3 on the front of the grate and to the right. Figure 30 NOTE: Allow 2" between the back log and the two front logs. Right Middle Log #5 Left Middle Log #4 LG848 Figure 30 Place Front Logs LG848 VWF30MO front logs 5. Place left middle log #4 as shown. Figure 31 6. Place right middle log #5 as shown.
log placement VWF Series Vented Gas Log Set Shield Plate VWF36 massive oak logs 1. Slide shield plate behind burner pan. Figure 34 Burner Pan LG852 Figure 34 Slide Shield Plate Behind Burner Pan Rear Log #1 Lg852 2. Center rear log #1 on grate bars and plate flush with VWF30 rear of theshield grate. Figure 35 LG853 Figure 35 Center Rear Log on Grate LG853 VWF30MO rear log Right Front Log #4 Left Front Log #2 3. Place front left log #2 in front of the plate and to the left.
log placement VWF Series Vented Gas Log Set Right Side Middle Log #7 Left Side Log #6 Right Side Log #10 6. Install left side log #6. Figure 37 7. Install right side middle log #7. Figure 37 8. Install right side log #10. Figure 37 Top Left Middle Log #8 LG855 Figure 37 Place Left & Right Side Logs and Right Side Middle Logs LG855 VWF30MO middle logs 9. Install top left middle log #8.
log placement VWF Series Vented Gas Log Set VWF18 American oak logs Rear Log #1 NOTE: Each log has an identifying number embossed on bottom surface. 1. Place Back Log #2 on grate bars on back of grate. Figure 41 Front Log #1 Figure 41 Place Rear Log on Grate Bars LG859 LG859 VWF18AO rear log 2. Place Front Log #1 on front of grate. Figure 42 LG860 Figure 42 Place Front Log Right/Left Middle Log #4 Right/Left Middle Log #4 LG860 Middle Log #4 on top 3.
log placement VWF Series Vented Gas Log Set VWF24 American oak logs Rear Log #1 NOTE: Each log has an identifying number embossed on bottom surface. 1. Place Back Log #2 on grate bars on back of grate. Figure 45 Front Log #2 Figure 45 Place Back Log on Grate LG863 LG863 VWF24AO rear log 2. Place Front Log #1 on front of grate. Figure 46 Figure 46 Place Front Log on Grate LG864 Right/Left Log #4 Right Log #3 LG864 VWF24AO front log 3. Position Right Log #3 on top right of Log #1 and Log #2.
log placement VWF Series Vented Gas Log Set VWF30 American oak logs Rear Log #2 NOTE: Each log has an identifying number embossed on bottom surface. 1. Place Back Log #2 on grate bars on back of grate. Figure 49 LG867 Figure 49 Place Rear Log on Grate Front Log #1 LG867 VWF30AO rear log 2. Place Front Log #1 on front of grate. Figure 50 LG868 Figure 50 Place Front Log Left Middle Log #4 LG868 Right/Left Middle Log #4 3.
log placement VWF Series Vented Gas Log Set Left Crossover Log #7 7. Place Left Crossover Log #7 on Log #2 and Log #5. Figure 53 Right Crossover Log #8 Figure 53 Place Left Crossover Log #7 LG871 LG871 8. Place Right Crossover VWF30AO left crossLog log#8 on Log #3 and Log #7.
log placement VWF Series Vented Gas Log Set models VWF24B (6 Logs) Top Left Log #6 Figure 55 1. Slide shield plate down back of burner pan. 2. Place Back Log #1 on grate bars on back of grate. 3. Place Middle Log #2 in front of Log #1. 4. Position Right Front Log #3 on right front side of grate. 5. Position Left Front Log #4 on left front side of grate. Make sure notch in bottom of log sits on grate prong. 6. Rest Top Right Log #5 across top right sides of Log #1 and Log #2. 7.
log placement VWF Series Vented Gas Log Set models VWF24/18 split river oak 1. Slide shield plate behind burner pan. Figure 57 Shield Plate Burner Pan Rear Log #1 Figure 57 Slide Shield Plate Behind Burner Pan LG837 LG837 2. Place Rear Log #1 on back of grate. VWF18 shield plate Figure 58 LG875 Bottom Right Log #3 1st Grate Prong 2nd Grate Prong Figure 58 Place Rear Log 4th Grate Prong 3rd Grate Prong 3. Place Front Left Log #2 in front of back log on left arm of grate.
log placement VWF Series Vented Gas Log Set Bottom Front Left Log #5 5. Rest Bottom Left Log #5 on back log #1 and to the outside of the first grate prong. Figure 60 6. Rest right end of Top Right Log #4 on bottom right log. Figure 60 LG877 Top Right Log #4 Figure 60 Place Bottom Front Left and Top Right Logs Top Center Log #7 LG877 2418 SRO logs 5 4 7. Place end of Top Left Log #6 on bottom left log. Rest the other end between the first and second grate prongs. Figure 61 8.
log placement VWF Series Vented Gas Log Set models VWF30/24 split river oak Shield Plate 1. Slide shield plate behind burner pan. Figure 62 Burner Pan Figure 62 Slide Shield Plate Behind Burner Pan LG830 Rear Log #1 LG830 2. Place Back Log #1 on back of VWF24 shield grate. Figure 63 First Grate Prong Fifth Grate Prong LG879 Bottom Right Log #3 Fourth Grate Prong Second Grate Prong Third Grate Prong Figure 63 Place Rear Log 3.
log placement VWF Series Vented Gas Log Set Bottom Front Left Log #5 5. Rest right end of Top Right Log #4 on bottom right log. Figure 65 6. Rest Bottom Left Log #5 on back log #1 and to the outside of the left grate prong. Figure 65 Top Right Log #4 LG881 Figure 65 Place Top Right and Bottom Front Left Logs Top Center Log #7 LG881 3024SRO bot frt top right logs 7. Place end of Top Left Log #6 on bottom left log. Rest the other end between the first and second grate prongs. Figure 66 8.
log placement VWF Series Vented Gas Log Set models VWF36/30 split river oak Shield Plate 1. Slide shield plate behind burner pan. Figure 67 Burner Pan Figure 67 Slide Shield Plate Behind Burner Pan Rear Log #1 LG852 Lg852 VWF30 shield plate First Grate Prong Sixth Grate Prong 2. Place Back Log #1 on back of grate. Figure 68 LG883 Second Grate Prong Third Grate Prong Figure 68 Place Rear Log Fifth Grate Prong Fourth Grate Prong Bottom Right Log #3 LG883 3630SRO rear log 3.
log placement VWF Series Vented Gas Log Set Bottom Front Left Log #5 5. Rest right end of Top Right Log #4 on bottom right log. Figure 70 6. Rest Bottom Left Log #5 on back log #1 and to the outside of the left grate prong. Figure 70 Top Right Log #4 Figure 70 Place Top Right Log and Bottom Front Left Log LG885 LG885 3630SRO Logs 4&5 7. Place end of Top Left Log #6 on bottom left log. Rest the other end between the first and second grate prongs. Figure 71 8.
log placement VWF Series Vented Gas Log Set models VWF18 split Pine 1. Slide shield plate behind burner pan. Figure 72 Shield Plate Burner Pan Figure 72 Slide Shield Plate Behind Burner Pan Right Front Log #1b LG837 Left Front Log #1a 2. LG837 VWF18 Place Left Front shield Log #1aplate on front left of grate. Figure 73 3. Place Right Front Log #1b on front right of the grate. Figure 73 LG887 Figure 73 Place Front Logs Side Support Log #2 LG887 VWF18 SP front logs 4.
log placement VWF Series Vented Gas Log Set Rear Log #3 5. Fit cutout in the bottom left of Rear Log #3 over the back end of log #1a. Rest right end of Log #3 on rear grate bar. Figure 75 Right Log #4 LG889 Figure 75 Place Rear Log LG889 VWF18SP rear log 6. Rest front end of Right Log #4 on right top of Log #1b. The back end of Log #4 rests to right hump on Log #3. Figure 76 Right Middle Log #5 Figure 76 Place Right Log LG890 LG890back end of Right Middle Log 7. Place VWF18SP right log#4.
log placement VWF Series Vented Gas Log Set Top Center Log #7 8. Lay Top Center Log #7 across log #5 with back end resting on Log #3. Figure 78 LG892 Figure 78 Place Top Center Log LG892 VWF18SP Top ctr log Top Left Log #8 9. Place front end of Top Left Log #8 on Log #1a. Let back end of Log #8 rest on Log #7.
log placement VWF Series Vented Gas Log Set models VWF24 split Pine Shield Plate 1. Slide shield plate behind burner pan. Figure 80 Burner Pan Right Front Log #1b Left Front Log #1a LG830 Figure 80 Slide Shield Plate Behind Burner Pan 2. Place left front log #1a on front left of grate. Figure 81 3. Place LG830 right front log #1b on front right of the grate. Figure 81 VWF24 shield LG831 Figure 81 Place Front Logs Side Support Log #2 LG831 front logs 4.
log placement VWF Series Vented Gas Log Set Right Log #4 6. Rest front end of right log #4 on right top of log #1b. The back end of log #4 rests to right hump on log #3. Figure 84 Figure 84 Place Right Log 7. LG834 Right Middle Log #5 Left Log #6 LG834 Place front of right middle VWF24 right log log #5 on top right of log #1b. Rest back end of log #5 on top right of log #4. Figure 85 8. Rest front end of left log #6 on log #1a and back end of log #6 just left of middle log #1.
log placement VWF Series Vented Gas Log Set models VWF30 split Pine 1. Slide shield plate behind burner pan. Figure 89 Shield Plate Burner Pan Figure 89 Slide Shield Plate Behind Burner Pan Right Front Log #1b Left Front Log #1a 2. LG821 LG821 Place left front log #1a on front left of grate. shield plate Figure 90 3. Place right front log #1b on front right of the grate. Figure 90 LG822 Figure 90 Place Front Logs Side Support Log #2 LG822 4.
log placement VWF Series Vented Gas Log Set Left Log #6 Right Log #4 6. Rest front end of right log #4 on right top of log #1b. The back end of log #4 rests to right hump on log #3. Figure 93 7. Rest front of left log #6 just left of the middle of log #1a and back end of log #6 just left of middle of log #3. Figure 93 Right Middle Log #5 LG825 Figure 93 Place Left and Right Logs 8. Place front of right middle log #5 on top LG825 right of log #1a.
log placement VWF Series Vented Gas Log Set Model VWF24/18WP Weathered PINE LOG Shield Plate 1. Slide shield plate behind burner pan. Figure 97 Burner Pan Figure 97 Slide Shield Plate Behind Burner Pan Rear Log #1 LG837 LG837 VWF18 shield plate Rear Stand of Grate Figure 98 Place Rear Log 2. Place Rear Log #1 on back of grate. Left side should fit on grate in front of rear stand. Right side goes on the rear stand of grate.
log placement VWF Series Vented Gas Log Set Top Left Log #5 Top Right Log #4 5. Place Top Right Log #4 on Bottom Right Log #2 resting on grate. Figure 100 6. Place Top Left Log #5 behind Rear Log #1 on the notch on rear left of grate stand. Figure 100 7. Place Mid Front Log #6 on grate between center and middle left grate bars. Fit notch on back of log on the cross grate bar.
log placement VWF Series Vented Gas Log Set Model VWF30/24WP Weathered PINE Shield Plate LOG 1. Slide shield plate behind burner pan. Figure 101 Burner Pan Rear Log #1 Figure 101 Slide Shield Plate Behind Burner Pan LG830 2. Place Rear Log #1 on back of grate. Left side should fit on grate in front of LG830 rear stand. Right side goes on the rear VWF24 shield stand of grate. Figure 102 LG897 Figure 102 Place Rear Log LG897 3024WP rear log Bottom Right Log #2 3.
log placement VWF Series Vented Gas Log Set Top Right Log #4 Bottom Left Log #3 4. Place Top Right Log #4 on Bottom Right Log #2 resting on grate. Figure 104 5. Place Bottom Left Log #3 on grate. The “V” of the log should straddle the end grate bar. Figure 104 LG899 'V' Straddling Grate Bar Figure 104 Place Bottom Left and Top Right Logs LG899 3024WP logs 3 & 4 6. Place Top Left Log #5 behind rear log #1 on the notch on rear left of grate stand. Figure 105 7.
log placement VWF Series Vented Gas Log Set Model VWF36/30WP Weathered PINE LOG Shield Plate 1. Slide shield plate behind burner pan. Figure 106 Burner Pan LG830 Figure 106 Slide Shield Plate Behind Burner Pan Rear Log LG830 2. Place Rear Log #1 on back of grate. VWF24 shield Left side should fit on grate in front of rear stand. Right side goes on the rear stand of grate. Figure 107 Figure 107 Place Rear Log LG901 Bottom Right Log #2 Bottom Left Log #3 LG901 3630WP back log 3.
log placement VWF Series Vented Gas Log Set Top Left Log #5 5. Place Top Right Log #4 on Bottom Right Log #2 resting on grate. Figure 109 6. Place Top Left Log #5 behind Rear Log #1 on the notch on rear left of grate stand. Figure 109 Top Right Log #4 LG903 Figure 109 Place Top Left and Right Logs Top Center Log #7 LG903 3630WP top logs 7. Place Mid Front Log #6 on grate between center and middle left grate bars. Fit notch on back of log on the cross grate bar. Figure 110 8.
OPERATING INSTRUCTIONS for spk AND CVTHL kits VWF Series Vented Gas Log Set safety INSTRUCTION FOR MANUAL CONTROL (SPK) AND Hi/Lo control (CVTHL) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING A. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: • Do not attempt to light any appliance.
operating instructions for MVVK Kits VWF Series Vented Gas Log Set NOTICE Millivolt CONTROL LIGHTING INSTRUCTIONS The Millivolt control does not come preassembled with an on/off switch so that it may be customized for the specific application with a wall switch, remote, etc. A switch/remote must be connected to enable the burner to light. STOP! Read the safety information label. Make sure the manual shutoff valve is fully open.
operating instructions for manvk kit VWF Series Vented Gas Log Set WARNING SAFETY INSTRUCTION FOR MANUAL control without pilot If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY READ BEFORE LIGHTING A. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
flame appearance VWF Series Vented Gas Log Set Checking Burner flames Flame should be yellow and extend vertically (not curling toward fireplace screen). Ember bed should have a yellow/orange glow LG909 Figure 111 Flame Appearance LG909 VWF30 Flame appearance pilot flame appearance Thermocouple/ Thermopile Tip The pilot flame must always be present when appliance is operating. It should just touch the top of the thermocouple/ thermopile tip.
fireplace draft test IMPORTANT: Fireplace Draft Test During Initial Installation It is critical to verify that your chimney is drafting properly because the fireplace and gas logs function as a system. WARNING Although Vermont Castings Group goes to great lengths to design vented gas log sets that minimize sooting, all vented log sets will soot over time. Sooting normally appears as areas of black powder-like substance on the logs.
cleaning and servicing REMOTE CONTROL RECEIVER REPLACEMENT The remote control receiver and batteries are very sensitive to heat. Exposure to high temperatures can cause the receiver to malfunction and shorten the life of the batteries. If your fireplace does NOT have a restrictive barrier (Page 6), such as glass doors, it is recommended that the remote receiver be affixed to the right hand side of the heat shield or placed in the front, right corner of the fireplace.
replacement Parts assembly VWF Series Vented Gas Log Set 1 2 3 4 8 6 5 7 Ref. 1. 2. 3. 4. 5. 6. 7. 8.
replacement Parts VWF Series Vented Gas Log Set 4 2 6 1 8 5 7 3 MASSIVE OAK LOGS Ref. 1. 2. 3. 4. 5. 6. 7. 8. Description Back Log Left Front Log Right Front Log Left Side Middle Log Right Side Middle Log Right Top Log Left Top Log Top Crossover Log Qty.
replacement Parts VWF Series Vented Gas Log Set AMERICAN OAK LOGS 1 Ref. 1. 2. 3. 4. 5. 6. 7. 7. 8. 2 4 6 3 Description Front Log Back Log Right Middle Log Left Middle Log Top Right Log Top Left Log Top Center Log Top Center Log Top Top Center Log Qty. 1 1 1 2 2 1 1 2 1 VWF18AO 27D8576 27D8577 -27D8580 ---27D8578 -- VWF24AO 27D8584 27D8585 27D8588 27D8580 -27D8587 ---- VWF30AO 27D8592 27D8593 -27D8580 27D8594 -27D8578 -27D8600 8 7 3 5 BIRCH LOGS Ref. 1. 2. 3. 4. 5. 6. Description Qty.
replacement Parts VWF Series Vented Gas Log Set 8 8 7 9 7 6 6 5 5 4 4 2 2 3 1a 3 1a 1b 1b SPLIT PINE LOGS Ref. 1a. 1b. 2. 3. 4. 5. 6. 7. 8. 9. 54 Description Front Left Log Right Front Log Side Support Log Rear Log Right Log Right Middle Log Left Log Top Center Log Top Left Log Top Top Left Log Qty.
replacement Parts VWF Series Vented Gas Log Set 1 2 WEATHERED PINE LOGS Ref. 1. 2. 3. 4. 5. 6. Description Rear Log Bottom Right Log Bottom Left Log Top Right Log Top Left Log Mid Front Log Qty. 1 1 1 1 1 1 VWF24/18WP 27D5140 27D5141 27D5142 27D5143 27D5144 27D5145 3 4 6 5 1 WEATHERED PINE LOGS Ref. 1. 2. 3. 4. 5. 6. 7. Description Rear Log Bottom Right Log Bottom Left Log Top Right Log Top Left Log Mid Front Log Top Center Log Qty.
VWF Series Vented Gas Log Set 56 27D7300
VWF Series Vented Gas Log Set 27D7300 57
VWF Series Vented Gas Log Set Massachusetts Residents Only — Please read and follow these special requirements 2. Approved Carbon Monoxide Detectors. Each carbon NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 when installed within the Commonwealth of Massachusetts.
LIMITED LIFETIME WARRANTY POLICY Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate, Stainless Steel Burners, and Vented Fiber Ceramic and Refractory Logs. Five Year Warranty The following components are warranted for 5 years to the original owner, subject of proof of purchase: Aluminized Burners.
Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.