User Manual

9
"Duzy" Series Vented Gas Log Sets
32D1999




WARNING
FP2857
millivolt wiring



Optional Wall Switch
or Remote Receiver
Switch
Millivolt
Valve
Pilot
Figure 8 -
Wiring Diagram
FP2857
The Millivolt (thermopile) is a self powered combination
gas control that does not require 110VAC to operate. See
Figure 8 and installation instructions provided with optional
wall switch or remote control for wiring instructions. A max-
imum length of 15 feet of 18awg two conductor wire is to
be used for wall switch. Note switches must be suitable
for millivolt operation.

The millivolt system and individual components may be
checked with a millivolt meter having a 1-1000 mV range.
Conduct each check shown in chart by connecting meter
test leads to terminals as indicated.
A. Complete Millivolt System Check
(“A” Reading - Contacts CLOSED - Control knob “ON”
- Main burner should turn ON)
1. If reading is more than 100 millivolts and the au-
tomatic valve still does not come on, replace the
control.
2. If the closed circuit reading (“A” reading) is less
than 100 millivolts, determine cause for low read-
ing, proceed to Section B.
B. Thermopile Output Reading Check
(“B” Reading - Contacts OPEN - Main burner OFF
1. 325 millivolts minimum. If the minimum millivolt
reading is not obtainable, readjust pilot for maxi-
mum millivolt output. If millivolt reading is still below
minimum specified, replace thermopile.
 
  
   
A Complete TH & THTP Minimum
System 100mV
B Thermopile TP & THTP Minimum
Output 325mV