User Manual
32D1999
"Duzy" Series Vented Gas Log Sets
4
Check your packing list to verify that all listed parts have
been received. You should have the following:
• Burner and Grate Weldment Assembly
• Lava Rocks (2)
• Glowing Embers (Rock Wool)
• Damper Clamp
• Installation /Operating Instructions
• Masonry Screws (2)
• 3/8" Aluminum tube with 3/8" 90° elbow, 1/2" to 3/8"
tube fitting
• Individual Logs
• Installation Instructions
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance.
Ensure that the following items are available before pro-
ceeding with installation:
• External regulator (for propane/L.P.G. only)
• Manual shutoff valve
• Piping which complies with local codes
• Pipe wrench
• Tee joint
• Pipe sealant approved for use with propane/L.P.G.
(Resistant to sulfur compounds)
• Drill with masonry bit (for mounting to the floor)
Natural *Propane (LP)
Inlet Minimum 6.0” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Regulator Pressure 4.0” w.c. 10.0” w.c.
An external regulator is required to reduce supply pres-
sure to a maximum of 13” w.c.
•
•
VDY24/18NMP Nat. Manual (thermocouple) 50,000
VDY24/18PMP LP Manual (thermocouple) 50,000
VDY24/18NVP Nat. Millivolt (thermopile) 50,000
VDY24/18PVP LP Millivolt (thermopile) 50,000
VDY30NMP Nat. Manual (thermocouple) 65,000
VDY30PMP LP Manual (thermocouple) 65,000
VDY30NVP Nat. Millivolt (thermopile) 65,000
VDY30PVP LP Millivolt (thermopile) 65,000
Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
- All gas to the gas logs is shut off at the valve.
- Valve position to light/maintain a standing pilot.
- Valve position to light/maintain the gas burner.
- All gas to the gas logs is shut off at the valve.
- Valve position to light/maintain a standing pilot.
- Valve position to light/maintain the gas burner.