The floor of the fireplace is recessed below the fireplace opening. See Warnings on Page 6.
The fireplace has glass doors which when open reduces the opening width to 1Z\x" or more below
the stated minimum dimensions within the homeowner’s manual.
The floor of the fireplace is sheet metal without a brick covering.
The remote receiver is attached but does not physically fit inside the fireplace with 2" clearance
to the side wall.

Connect wires according to remote receiver instructions. The female terminals should be connected
to factory attached male terminals which are located on right hand side of the burner. Figure 54
 Do not let wires touch grate and/or burner.
For more details, see remote receiver instructions.
FP2857
millivolt wiring



Optional Wall Switch
or Remote Receiver
Switch
Millivolt
Valve
Pilot
Figure 54 -
Attach Remote Receiver Wires
to Terminals
FP2857
NOTE



  
 


 Battery life decreases as temperature increases.
Keep remote receiver in a low temperature area outside
of fireplace to prolong battery life.