Installation Instructions
30
Majestic • RUBY25IN, RUBY25IL, RUBY30IN, RUBY30IL, RUBY35IN, RUBY35IL Installation Manual • 2542-980 Rev. i • 9/19
Figure 6.5 Cover Plate Removal (Option 1)
INSTALL HALOGENS
OPTION 1
OPTION 2
Figure 6.6 Through Valve Plate Opening (Option 2)
INSTALL HALOGENS
D. Installation / Service for Halogens
REAR COVER PLATE
Option 2:
• Remove appliance front, glass, logs, base pan assem-
bly, burner assembly and valve plate assembly. See
Figure 6.6.
• Service / replace halogens. Figure 6.2 shows a wiring
diagram.
• Reinstall valve plate assembly, burner assembly, base
pan assembly, logs and appliance glass and front.
On units already installed, removal of decorative front and
gas insert may be required.
Option 1:
• Detach exible liner from top of unit if insert is installed by
removing the collar slide plate screw. See Figure 5.1.
• Remove the ve screws on the rear cover plate. See
Figure 6.5.
• Service / replace halogens. Figure 6.2 shows a wiring
diagram.
• Reinstall the rear cover plate back on the unit.
• Reattach exible liner and replace collar slide plate
screw. See Figure 5.1.