Installation Instructions
17
Majestic • RUBY25IN, RUBY25IL, RUBY30IN, RUBY30IL, RUBY35IN, RUBY35IL Installation Manual • 2542-980 Rev. i • 9/19
E. Hearth Extension
1/2 in.
Figure 3.16 Minimum Required 1/2 in. Gap to Bottom of Front
• All ooring and hearth material must remian below the
bottom of the surround. See Figure 3.17.
• Combustible ooring may be located in front of the
appliance. Exception - no vinyl / adhesive ooring.
See Figure 3.17.
• 1/2 inch gap under the bottom of the front must be
maintained. See Figure 3.16.
• A minimum 1/4 inch gap from the bottom of the appliance
to the metal oor of the solid fuel rebox is REQUIRED.
See side view in Figure 3.18.
• Combustible flooring underneath the appliance is
acceptable with a 1/4 inch gap. See Figure 3.18.
Mantels - Combustible
Figure 3.14 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible
Measurement to bottom
of appliance:
= 29-1/4 in. (25")
= 32-3/4 IN. (30")
= 36-1/4 IN. (35")
Measurement
from surround
opening.
12 in.
12 in.
SURROUND
Flooring & Hearth Material
SURROUND
YES
NO
Flooring & Hearth Material
Flooring & hearth material must remain below the bottom of surround
Figure 3.17 Flooring & Hearth Material