Hearth & Home Technologies • Power Vent Inline (PVI-SLP) Instructions • 2196-900 Rev. AC • 12/15
H
2
V
3
V
2
H
1
V
1
A DVP-2SL ADAPTER
is required in this position
in the vent run on certain
models. See Table 2.1.
WARNING! Risk of Overheating!
- Minimum inital length of vent pipe required between
appliance and vertically positioned PVI-SLP.
- Must include two 90 degree elbows.
Top Vent - Horizontal Termination - (continued)
Figure 2.4 Vertical PVI Orientation
Minimum Maximum
H
1
+ V
1
+ V
2
24 in. 610 mm See Chart in Section 2.C: "Vent-
ing Length - Model Categories
and Length Requirements by
Termination Type."
V
3
0 in. 0 mm
H
2
18 457 mm
A minimum of 2ft. of vertical piping is required between the appliance
and the PVI-SLP in addition to the minimum venting described above
when installing PVI-SLP with certain appliance models. See Table 2.1.
V minimum = 2 ft. and V
2
+ H
1
+ V
1
minimum = 4 ft. for certain appliance
models. See Table 2.1.
Note: 1 ft. of vertical drop decreases
total allowable length by 2 ft.
WARNING! Risk of Fire! Use DVP pipe between appliance
and PVI-SLP on these models:
ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36,
HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-
42, TRUE-50, CERONA-36, CERONA-42, MEZZO36,
MEZZO36ST, CRAVE4836, CRAVE4836ST, MEZZO48,
MEZZO48ST, CRAVE6048, CRAVE6048ST, MEZZO60,
MEZZO60ST, CRAVE7260, CRAVE7260ST, MEZZO72,
MEZZO72ST, CRAVE8472, CRAVE8472ST
Combustibles surrounding pipe may overheat.
Note: For PRIMO models, see the PRIMO Installation
Manual for vent confi gurations.