Installation Manuel

6
Hearth & Home Technologies • Power Vent Inline (PVI-SLP) Instructions • 2196-900 Rev. AC • 12/15
H
1
H
2
V
2
V
3
V
1
A DVP-2SL ADAPTER
is required in this position
in the vent run on certain
models. See Table 2.1.
WARNING! Risk of Overheating!
- Minimum inital length of vent pipe required between
appliance and vertically positioned PVI-SLP.
- Must include two 90 degree elbows.
NOTICE: If pipe configuration includes a vertical component that goes
downward, a vertical component going back upward is not allowed.
Figure 2.3 Vertical PVI Orientation
Minimum Maximum
H
1
+ V
1
+ V
2
24 in. 610 mm
See Chart in Section 2.C: "Venting Length - Model Cat-
egories and Length Requirements by Termination Type."
H
2
18 in. 457 mm
V
3
0 in. 0 mm
A minimum of 2 ft. of vertical piping is required between the appliance and the PVI-SLP in addition
to the minimum venting described above when installing PVI-SLP with certain appliance models.
See Table 2.1. V minimum = 2 ft. and V
2
+ H
1
+ V
1
minimum = 4 ft. for certain appliance models.
See Table 2.1.
Note: 1 ft. of vertical drop decreases
total allowable length by 2 ft.
WARNING! Risk of Fire! Use DVP pipe between appliance and PVI-SLP on these models:
ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE-
50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, CRAVE4836, CRAVE4836ST, MEZZO48, MEZZO48ST,
CRAVE6048, CRAVE6048ST, MEZZO60, MEZZO60ST, CRAVE7260, CRAVE7260ST, MEZZO72, MEZZO72ST,
CRAVE8472, CRAVE8472ST
Combustibles surrounding pipe may overheat.
Note: For PRIMO models, see the PRIMO Installation Manual for vent con gurations.