STEP 4
GROUND
WHT
AUX RC300
MODULE
AUX 1
AUX 2
8K1-PVI
TO JUNCTION BOX
110VAC
ACCESSORY
CABLE
ORG
TO JUNCTION BOX
110VAC
8K1-PVI
WIRE
HARNESS
BROWN
RED
STEP 2
STEP 3
STEP 5
VALVE
ORANGE
(PILOT)
GREEN
(MAIN)
STEP 1
STEP 6
Figure 4.4 PVI Wiring - IntelliFire
TM
Ignition System
IntelliFire IPI Module (Green)
1. Attach the new 8K1-PVI module to the 6V transformer.
2. Connect the pilot wires (white to S and orange to I) to
the 8K1-PVI module.
3. Connect the new Aux RC300 to the 8K1-PVI module.
4. Plug the Aux RC300 into the Junction Box.
5. Attach the 8K1-PVI wire harness to the 8K1-PVI
module. Connect green and orange valve wires and
reconnect ground wire to chassis.
6. Connect the accessory cable coming from the PVI to
the AUX RC300 (AUX 2 port) and the corresponding
colored wire on the wire harness.