Installation Manuel

2
Hearth & Home Technologies • Power Vent Inline (PVI-SLP) Instructions • 2196-900 Rev. AC • 12/15
B. Installation of PVI-SLP
1. INSTALLATION PRECAUTIONS
a. This device must be installed by a quali ed installer
in accordance with these instructions.
b. Safety inspection of the venting system should
be performed before and after installation of this
power vent. Consult local code of cials and follow
applicable installation codes.
c. DO NOT INSTALL DAMAGED EQUIPMENT OR
VENT COMPONENTS.
d. Disconnect electrical power supply before making
wiring connections.
e. Venting of more than one appliance in a common
vent system is prohibited.
f. Clearances between the vent pipe and combustible
materials must be maintained at 1-1/2-inch top,
1-inch sides and bottom.
g. All outer pipe joints must be sealed with high tem-
perature silicone. See Section 2.A.
h. The access panel opening must be located such
that access for service and adjustment is available.
The NEC requires a minimum of 30 inches of space
around the opening and 36 inches in front of the
opening to the access panel. Consult of cials hav-
ing jurisdiction regarding regional requirements.
CAUTION! Failure to install, operate, and maintain the
power venting system in accordance with manufacturer's
instructions will result in conditions which may produce
bodily injury and/or property damage.
6VDC POWER RECEPTACLE
2326-131
BLOWER ASSEMBLY
2196-025
VACUUM SWITCH
2196-326
NOTE: Wire Harness connecting PVI to appliance sold separately.
The length of wire harness needed varies by installation.
8K1-PVI
2196-150
8K1-PVI
WIRE HARNESS
2196-200
AUX300
MODULE
2166-335
AUX 1
AUX 2
Figure 1.1 Service Parts
2. INSTALLATION GUIDELINES
WARNING: RISK OF FIRE AND BURNS. DO NOT
install PVI-SLP with the access panel facing upward.
Overheating may occur.
NOTICE: Installation of the PVI-SLP in an attic is not
recommended in regions where temperatures reach 0°F
(-18°C) and relative humidity exceeds 60% simultaneously.
Low temperatures and high moisture content may cause
the PVI-SLP to freeze.
a. If the PVI-SLP is being installed in a con ned space
(such as a utility closet, mechanical room or attic space)
with a total volume less than 250 cubic feet, an access
hole with minimum dimensions of 8 inches by 16 inches
will be required directly in front of the access panel.
The recommended access hole size is 12 inches by 17
inches. This size will allow full access to the 11 inch x
16 inch access panel on the PVI-SLP. See Figure 3.1.
The con ned space where the PVI is installed, and the
space to which the access hole opens, must add up to
at least 250 cubic feet. This hole may be covered with
a decorative cover as long as the cover has a minimum
of 50% open air. If the PVI-SLP is being installed in a
space greater than 250 cubic feet the access hole is still
required, but a solid cover may be used. This also applies
to a replace chase.
The decorative cover CANNOT be located on an outside
wall that is open to the environment.
b. For installations near loose- ll insulation (such as attics)
a minimum clearance of six inches must be maintained
between the access panel and the insulation.
c. The PVI-SLP CANNOT be installed with the access
panel facing upward.
d. The exit termination of mechanical draft systems shall
not be less than seven feet above grade when located
adjacent to public walkways.
e. A mechanical drafting venting system shall terminate at least
three feet above any forced air inlet located within 10 feet.
A. Components and Service Parts List
Service Parts List
Replacement parts can be obtained from your dealer. Repair of the Power Vent should only be done by a quali ed service technician.
Required Wire Harness
Lengths Available Part Number
10 ft. PV Wire Harness PVI-WH10
20 ft. PV Wire Harness PVI-WH20
40 ft. PV Wire Harness PVI-WH40
60 ft. PV Wire Harness PVI-WH60
80 ft. PV Wire Harness PVI-WH80
100 ft. PV Wire Harness PVI-WH100
NOTICE: The blower motors present in this powervent
will generate sound during operation. The effects of the
increased sound level can be minimized with careful
planning during installation of the system. Locating the
powervent service access grill in an area remote of im-
mediate living space will reduce the effects of the added
sound generated during operation.