Installation Manuel
19
Hearth & Home Technologies • Power Vent Inline (PVI-SLP) Instructions • 2196-900 Rev. AC • 12/15
INSTALLATION
The type of control used to power the appliance is the de-
termining factor in making the appliance compatible with
the PVI-SLP. Table 4.1 indicates which set of instructions
to use.
• A 7/8 in. diameter hole must be bored in the side of
the fi replace outer wrap in which the 5 wires from the
power vent will be routed. The hole should be located
2 inches to the side of the junction box and 4-inches
up from the base of the fi replace.
CONTROL REFERENCE
RC100
RC200
RC300
FIGURE 4.3
FIGURE 4.4
IntelliFire™ Plus IPI Module (Black)
1. Attach the new 8K1-PVI module to the 6V transformer.
2. Connect the pilot wires (white to S and orange to I) to
the 8K1-PVI module.
3. Connect the new Aux RC300 to the 8K1-PVI module.
4. Plug the Aux RC300 into the Junction Box.
5. Attach the 8K1-PVI wire harness to the 8K1-PVI
module. Connect green and orange valve wires and
reconnect ground wire to chassis.
6. Connect the accessory cable coming from the PVI to
the AUX RC300 (AUX2 port) and the corresponding
colored wire on the wire harness.
7. Connect the stepper motor wires to the 8K1-PVI
module.
STEP 4
VALVE
ORANGE
(PILOT)
GREEN
(MAIN)
GROUND
WHT
AUX RC300
MODULE
AUX 1
AUX 2
8K1-PVI
TO JUNCTION BOX 110VAC
ACCESSORY CABLE
ORG
TO JUNCTION BOX
110VAC
8K1-PVI
WIRE HARNESS
BROWN
RED
STEP 1
STEP 2
STEP 3
STEP 5
STEP 6
STEP 7
Figure 4.3 PVI Wiring - IntelliFire
TM
Plus (RC100, RC200, RC300 Controls)
Table 4.1.
NOTICE: When installing the power vent with the
MEZZO and CRAVE models, the LED will need to
be disconnected from the AUX2 (factory setting) and
moved to AUX1. Plug the power vent system into
AUX2. The LED function will only be operational on
the HIGH setting.