Installation Manuel
17
Hearth & Home Technologies • Power Vent Inline (PVI-SLP) Instructions • 2196-900 Rev. AC • 12/15
A. Wiring the Appliance for the PVI-SLP
NOTICE: Electrical wiring must be done in accordance
with national, provincial, and/or local electric codes.
CAUTION! Risk of shock! Disconnect electrical power
from fi replace/power vent before performing any mainte-
nance, repair, or electrical wiring.
NOTICE: Electrical service of 120 VAC-60Hz must be
supplied to the junction box of the fi replace in order for the
power vent to operate correctly.
NOTICE: The 8K1-PVI control module must be used to
integrate the PVI-SLP to the fi replace.
4
4
Electrical Information
TO JUNCTION
BOX (110V)
MODULE
FLAME
SENSE
IGNITER
GROUND
ORANGE
(P
ILOT)
GREEN
(MAIN)
BROWN
BLACK
RED
BATTERY PACK
6V DC (AA X 4)
THERMOSTAT WIRE
ASSEMBLY / WALL
SWITCH WIRE
STEP 2
STEP 1
STEP 4
STEP 5
STEP 3
STEP 6
Figure 4.1 IntelliFire™ Plus (Black) IPI Module Wiring as Shipped from Factory
REMOVAL OF UNNECESSARY PARTS
Refer to the appropriate directions depending on the color
of the IPI module (Black or Green.)
IntelliFire™ Plus IPI Module (Black)
Refer to Figure 4.1 for steps 1 through 5. The shaded
portion corresponding to the numbered step is the task to
be performed.
1. Unplug control module power.
2. Detach the white and orange wires from the control
module.
3. Detach the remaining harnesses from the control mod-
ule.
4. Remove the black control module. This will no longer
be needed.
5. Remove and discard battery pack (if present).
6. Remove and discard IPI wire harness.
NOTICE: IntelliFire
TM
Plus models with PVI-SLP installed
may only be used with the RC100, RC200 or RC300 remote
to turn on fi replace.