Installation Manuel
14
Hearth & Home Technologies • Power Vent Inline (PVI-SLP) Instructions • 2196-900 Rev. AC • 12/15
Figures 3.4 - 3.6 show possible framing techniques.
ACCESS PANEL
WARNING! Risk of fire and burns! DO NOT install PVI-SLP with
the access panel facing upward. Overheating may occur.
Note: An 8 X 16 inch (minimum dimensions) framed hole is required in
front of the access panel. This hole may be covered with an open air
louvered cover. The recommended access hole size is 12 inches by 17
inches. This size will allow full access to the 11 inch x 16 inch access
panel on the PVI-SLP.
ACCESS PANEL
Figure 3.4 PVI-SLP Mounted to Horizontal Surface
ACCESS PANEL
Note: A framed hole with mini-
mum dimensions of 8 inches x
16 inches is required in front of
the access panel.
This hole may be covered with
an open air louvered cover. The
recommended access hole size
is 12 inches by 17 inches. This
size will allow full access to the
11 inch x 16 inch access panel
on the PVI-SLP.
Figure 3.5 PVI-SLP Mounted to Vertical Surface
Figure 3.6 Mount PVI-SLP to Chase
CHASE
APPLIANCE
Note: A framed hole is
required in front of the
access panel.
This hole may be covered
with an open air louvered
cover and must be a mini-
mum of 8 inches x 16
inches.
The recommended access
hole size is 12 inches by 17
inches. This size will allow
full access to the 11 inch x
16 inch access panel on the
PVI-SLP.
Figure 3.3 Access Panel Framing Dimensions
8 IN. MIN.
16 IN. MIN.
= OPTIONAL FINISH MATERIAL AROUND ACCESS PANEL
TOP
CENTER AIR
OPENING OVER
ACCESS PANEL