PH Gas Logs
65D2035
PH18NM Nat. Manual 18,000 30,000
PH18NV Nat. Millivolt 26,000 30,000
PH24NM Nat. Manual 19,000 36,000
PH24NV Nat. Millivolt 24,000 36,000
PH18PM LP Manual 22,500 30,000
PH18PV LP Millivolt 24,500 30,000
PH24PM LP Manual 25,000 36,000
PH24PV LP Millivolt 29,000 36,000
Natural Propane (LP)
Manual Regulator Pressure 4.0” w.c. 10.0” w.c.
Millivolt Regulator Pressure 3.5” w.c. 10.0” w.c.
Millivolt Pilot Regulator 3.5” w.c. n/a
Max. Gas Inlet Pressure 10.5” w.c. 13.0” w.c.
Min. Gas Inlet Pressure 5.0" w.c. 11.0" w.c.
An external regulator is required to reduce supply
pressure to a maximum of 13.0" w.c. for LP systems.
Piezo ignitor allows ignition of the pilot without the
use of matches or batteries.
- All gas to the gas logs is shut off at
the valve.
- Valve position to light/maintain a
standing pilot.
- Variable position corresponding to
desired ame height.
- All gas to the gas logs is shut off at
the valve.
- Valve position to light/maintain a
standing pilot.
- Valve position to turn ON/OFF log
set with remote switch/thermostat.
- Variable position to control ame
height (heat output).
The gas log heater is tted with a specially designed
safety pilot (ODS assembly) which senses the amount
of oxygen available in the room and shuts the gas log
heater off if the oxygen level begins to drop below
a satisfactory level. The pilot can only be relit when
adequate fresh air is available.
The millivolt gas log pilot is tted with a millivolt
(thermopile) generator to provide power for remote
activation.