User Manual

12
PH Gas Logs
65D2035

1. Center the gas log unit in the replace or rebox.
2. Install Grate: Insert longest middle grate bar in one of
the two square holes in control panel. Figure 11. Be sure
grate is centered. Sit horizontal bar inside two hooks
on front of control panel. Figure 11. Make certain front
feet of grate are located inside front edge of replace
or rebox.
3. Anchor holes are located on the ange of the unit. Figure
11. After centering the burner correctly, mark the hole
positions on the replace/rebox oor. Drill two (2) 5/32"
diameter holes approximately 1Z\x" deep.
4. Anchor the unit to the replace/rebox oor using the
screws provided. Figure 12.

FP2926
install grate
Screws
Hole for
Grate Bar
Middle
Grate Bar
Hooks for
Grate
Horizontal
Grate Bar
Anchor
Hole
Figure 11 -
Install Grate and Secure Heater to Floor
of Fireplace/Firebox
 A qualied gas appliance installer must
connect the heater to the gas supply. Consult all local
codes.
 Hold heater valve rmly with a wrench to
prevent movement when connecting to inlet pipe.



  




     



   

     

Figure 12
FP2371
gas connect
Stainless
Flexible
Tube
Pipe
Possible Locations
for Pressure
Tapping Point
Gas
Supply
Inlet
To
Heater
Valve
Pipe
Coupling
Manual Shutoff
Valve
FP2371
Figure 12 -
Gas Connection
      










, to reduce the supply tank pressure to a maximum of
13" w.c. This is in addition to the internal regulator in the
heater valve.