User Manual
11
PH Gas Logs
65D2035
• Turn the gas supply to the replace or re-
box.
• Seal any fresh air vents and/or ash clean-out doors
located on the oor or wall of the replace. If left
unsealed, drafting may cause pilot outage or soot-
ing. Use a heat resistant sealant.
Manual and millivolt controlled gas logs may be installed as
a vented decorative log set in compliance with ANSI Z21.60
and National Fuel Gas Code, Section 6.6 Since, the gas
logs are operated with the damper open, non-combustible
material and minimum mantel requirements do not apply.
Exception:
• Turn off gas supply to replace or rebox.
• Have the replace oor and chimney professionally
cleaned to remove ashes, soot, creosote or other
obstructions. Have this cleaning performed annually
after installation.
• Seal any fresh air vents or ash clean-out doors lo-
cated on oor or wall of replace. If not, drafting may
cause pilot outage or sooting. Use a heat-resistant
sealant. Do not seal chimney ue damper.
A damper stop must be provided with the unit. Contact your
dealer to obtain one. The damper stop must be installed as
shown in Figure 10 to prevent full closure of the replace
damper blade and provide a minimum 29 square inch ue
opening.
FP2538
damper stop
Damper
Stop
Damper
FP2538
Figure 10 -
Damper Stop Installation
(See Warning)
Placement in a
Fireplace with Restrictive Barrier