The gas log heater must be installed at least 5" above any combustible ooring material,
such as carpeting or tile, which is closer than 14" to the base of the replace. The minimum
distance must be maintained from the top surface of carpeting, tile, etc. Figure 8
,
The gas log heater may be installed nearer to the oor if a minimum of 14" of noncombus-
tible material such as slate or marble is installed between the base of the replace and the
combustible ooring. Figure 9
5” Minimum
FP2924
min comb floor clear
Heater in Fireplace
or Firebox
Combustible
Material
FP2924
Figure 8 -
Minimum Clearance Above Combustible Flooring
14” Minimum
FP2925
min noncomb floor clear
This
Distance
May Now
be Less
than 5"
Heater in
Fireplace or
Firebox
Combustible
Material
FP2925
Figure 9 -
Minimum Clearance Above Combustible Flooring with
Noncombustible Material Installed at Base of Fireplace