User Manual

7
PH Gas Logs
65D2035




Exception: 



Use manufacturer’s installation and clearance require-
ments as dened in their manual.
The PH Series unvented room heater is approved for instal-
lation into the following unvented replaces:

The PH Series unvented room heater may also be installed
into a Ventless Firebox Enclosure for Gas Fired Decorative
Type Unvented Room Heaters per ANSI Z21.91b.2004,
as long as rebox hearth dimensions meet the minimum
hearth dimensions shown below.
C
A
D
B
FP2530
hearth dims
  
PH18 25” 13” 17Z\x 17”
(635 mm) (330 mm) (445 mm) (432 mm)
PH24 29” 13” 19Z\x 17”
(737 mm) (330 mm) (495 mm) (432 mm)
Figure 1 -
Hearth Minimum Dimensions
FP2530


      
 




The following are guidelines for placing a gas log set in
a replace that has a restrictive barrier along the bottom
front opening of the replace. Some examples of barri-
ers are glass/screen door frames and sunken/recessed
replaces.
 
 
No Restriction 13”
0” to 1Z\x 16”
Greater than 1Z\x” to 3” 16”
Greater than 3” *
*Any barrier greater than 3” placed in front of the gas log
set is not recommended by the manufacturer.
 Non combustible material such as refractory brick
may be used to line the oor of the replace in order to raise
the height of the gas log set in relation to a restrictive barrier.
If the unit is raised, the minimum height dimension listed in
the homeowner’s manual must not be exceeded.
 If the log set is equipped with a remote receiver, a
restrictive barrier may reduce the battery life by increasing
the ambient temperature inside the replace. Placement
of the receiver outside of the replace will extend the
battery life.
Depth of Fire-
place/Firebox
(Refer to
Table)
The log set should
be placed against or
as near as possible
to the rear wall of
the replace
Glass door frames
with adjustable
louvers should
have the louvers
fully open while
the unit is in
operation
Height of restrictive bar-
rier caused by glass door
frames, recessed replaces,
etc. from the base or bottom
surface of the unit. (Refer to
Table).
Figure 2 -
Reference Drawing of a Natural
Flame Log Set in an Enclosure
FP2794