Installation and Operation
15
26D4720
MCUF Series Vent-Free Firebox
Optional brass trim kits can be used with unit when installed 
as a free standing replace with wood surround.
The optional wide canopy can be installed. See installation 
instructions provided with kit.
(BLOTMC)
If  you  are  installing  the  forced  air  kit,  Model  BLOTMC, 
on MCUF36 or MCUF42 models, refer to the installation 
instructions provided with the kit for electrical wiring require-
ments, or the blower installation section.  The rebox must 
be connected to main power supply at time of rebox instal-
lation. The blower must be installed prior to the installation 
of  the  vent-free  heater. The  electrical  connections  must 
be made before the rebox is framed and enclosed in the 
nished walls.
Any of the original wire as supplied with the replace must 
be replaced. Contact dealer for proper replacement wiring 
harness. (see parts list for part number). 120 volts, 60Hz, 
1 amp.
Electrical  power  cord  (plug)  can  be  routed  to  exit  the 
MCUF36/MCUF42 on either the left side or the right side. 
Remove cord protector from side of unit, route power cord 
through hole opposite side. Reinstall cord protector.
 Always check local building codes. The 
installation must comply with local regulations as well as 
the national electric codes.
   
     
     
    
       
     
    
      
110/115V AC
OFF
Fan Switch
ON
Black
White
Green
Thermostat
Control
Blower
Motor
Black
FP2847
BLOTMC wiring
Figure 20 - 
BLOTMC Wiring Diagram
1.  This should be done before framing the replace. Wire 
the receptacle into an electrical circuit. Wire with mini-
mum 60° C wire in accordance with prevailing codes.
2.  Remove the external junction box cover by removing 
the  screw  from  the  side  of  the  outside  rebox  wall. 
Junction box was installed at the factory.
3.  The junction box cover has a factory installed “romex” 
style strain relief connector. After connecting the wires, 
route the  wire  leads  through  this  connector.  Refer  to 
the wiring diagram in Figure 21.
FP1912
Junction box wiring
8/08
Figure 21 - 
Junction Box Wiring Diagram
Junction Box
Factory Supplied
Not Supplied
120V AC
60Hz