Installation Sheet

Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/198
B. Good Faith Wall Surface
NOTICE: Surface temperatures listed above are taken with
a temperature measuring probe as prescribed by the test
standard used for appliance certication. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 °F (17 °C) or
more depending on the thermometer settings and material
characteristics being measured. Use appropriate nishing
materials that are able to withstand these conditions. For
additional nishing guidelines, see Section 10.
If installing a television (TV) above the appliance, see
Section 3 of the appliance Owner’s Manual.
Figure 2.2 Good Faith Wall Surface Temperatures Above Appliance
(ECHEL60IN-C, ECHEL72IN-C)
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
245°F
APPLIANCE FRONT
190°F
155°F
140°F
135°F
125°F
125°F
FIREPLACE
OPENING
FACTORY-SUPPLIED NON-COMBUSTIBLE
BOARD SHOWN INSTALLED.
Figure 2.3 Good Faith Wall Surface Temperatures Above Appliance
with Passive Heat Kit Installed
Figure 2.1 Good Faith Wall Surface Temperatures Above Appliance
(ECHEL36IN-C/ECHEL36STIN-C, ECHEL48IN-C, ECHEL48STIN-C)
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
42 in.
12 in.
144°F
APPLIANCE FRONT
120°F
115°F
105°F
95°F
95°F
95°F
95°F
FIREPLACE
OPENING
FACTORY-SUPPLIED NON-COMBUSTIBLE
BOARD SHOWN INSTALLED.
OPTIONAL PASSIVE HEAT KIT INSTALLED
APPLIANCE FRONT
MEASUREMENTS FROM
TOP EDGE OF THE FIREPLACE
OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
170°F
155°F
145°F
140°F
130°F
125°F
125°F
FACTORY-SUPPLIED NON-COMBUSTIBLE
BOARD SHOWN INSTALLED.
FIREPLACE
OPENING
The ECHELON-C models may be installed with or without
optional heat management systems, including the Pas-
sive Heat kit. The installation of a heat management sys-
tem will affect certain aspects of the appliance installation
including framing dimensions and clearances to combus-
tibles. Note that Figure 2.3 in this section refers to the
wall surface temperatures when the Passive Heat kit is
installed.