Installation Sheet

63
Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/19
0-4 Inch Thickness-Inside Fit Method
0-4 Inches Finishing (Inside Fit):
See Figure 10.10 the required measurements to ensure
the proper t of the PFF. The top and bottom will have a
1/2 inch space from the PFF to the nished wall above
and below it. This is required to prevent the appliance
from overheating.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specied in
this manual. Overlapping materials could ignite.
Figure 10.10 Minimum Finished Opening Dimensions - Picture Frame Front - Inside Fit 0-4 Inch
24-3/8 IN.
ECHEL36IN-C/ECHEL36STIN-C = 47-1/4 IN.
ECHEL48IN-C/ECHEL48STIN-C = 59-1/4 IN.
ECHEL60IN-C = 71-1/4 IN.
4-7/16 IN.
4-7/16 IN.
4-1/8 IN.
4-1/2 IN.
1/2 IN. (TOP & BOTTOM) BETWEEN FINISHING MATERIAL
& PFF SURROUND FOR AIR FLOW
1/2 IN.
RECTANGULAR ACCESS HOLES COVERED
1/2 IN. (TOP & BOTTOM) BETWEEN FINISHING MATERIAL
& PFF SURROUND FOR AIR FLOW