Installation Sheet

Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/1962
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specied in
this manual. Overlapping materials could ignite.
1. Follow instructions provided with decorative front for
installation.
0-1 Inch Thickness Overlap Fit Method
The non-combustible nishing material, 0-1 inch thick,
should be installed up to the replace opening on the top
bottom and sides.
Use the factory-installed top nishing guard to ensure the
nishing material does not extend into the replace open-
ing.
See Figure 10.9 for minimum nished opening dimen-
sions.
Figure 10.9 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method (Picture Frame Front)
WARNING! Risk of Fire! DO NOT apply nishing mate-
rial beyond the top nishing guard and the bottom nish-
ing template. Appliance will overheat if nishing material
extends into appliance opening.
NOTICE: Decorative front will not t properly if nishing
material is applied beyond the nishing guard.
Picture Frame Front (PFF)
NOTICE: The nishing material thickness not only includes
the decorative nish materials (marble, tile, slate, etc) but
also the thin set, lath and adhesive used to attach the
decorative nish material.
Non-Combustible Finish Materials
Overlap Fit (0-1 Inch Thick Finishing Material Only)
Decorative Front Finishing Method Material Thickness Trim Ring
Picture Frame Front (PFF) Overlap Fit 0-1 inch Not included
Picture Frame Front (PFF) Inside Fit 0-4 Not included
FIREPLACE VIEWING AREA
15-3/4 IN.
51-1/8 IN. ECHEL48IN-C/ECHEL48STIN-C
39-1/8 IN. ECHEL36IN-C/ECHEL36STIN-C
63-1/8 IN. ECHEL60IN-C