Facing Material
Facing and/or nishing materials must not interfere with
air ow through decorative barrier fronts.
Facing and/or nishing materials must never overhang
into the glass opening.
Observe all clearances when applying combustible
materials.
Figure 10.2 Finishing and Facing Materials - Single-Sided Models
Finishing - Hearth
See Inside Fit or Overlap Method sections to determine
the necessary requirements for installation of a non-
combustible hearth for this model. Only hearths made of
non-combustible materials are allowed.
Decorative facing material thickness is measured from
the face of the installed non-combustible board. See
Figure 10.2 and Figure 10.3.
The fronts for this appliance are compatible with non-
combustible materials. See Figure 10.2 and Figure 10.3.
Refer to Section 1.E and 1.F of this manual for denitions
and qualications of non-combustible and combustible
materials.
Specic requirements for each method of installation are
described in this section.
Installation of nishing materials can be accomplished
by either the “overlap” or “inside-t” method, depending
on what type of decorative barrier front is to be installed.
See Figure 10.2 and 10.3. Overlap t decorative barrier
fronts include the Picture Frame Front. The Clean Face
Trim Front (CFT) can be either an inside t or an overlap
t. See Table 1.
BOTTOM
FINISHING
TEMPLATE
FINISHING
GUARDS
NON-COMBUSTIBLE
FINISHING MATERIAL
OVERLAP FIT = 0-1 IN. THICK
INSIDE FIT = 1-4 IN. THICK
1/2 IN. THICK WALL
SHEATHING
Decorative Barrier Front Finishing Method Material Thickness Trim Ring
Clean Face Trim (CFT)
Inside Fit 1-4 inches
Included & Not Used (Option #1)
Included & Used (Option #2)
Overlap Fit 0-1 inch Included & Used
Picture Frame Front (PFF) Overlap Fit 0-1 inch Not included
Picture Frame Front (PFF) Inside Fit 1-4 inches Not included
Table 1