A. General Information
WARNING! Risk of Shock! DO NOT wire 110-120 VAC
to the ignition module or to the appliance wall switch. (IPI)
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
Wire the appliance circuit using a minimum 14-2 AWG
with ground to unswitched 110-120 VAC. This is required
for proper operation of the appliance (IntelliFire™
ignition).
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
In some instances, the spark ignition of the replace may
cause intermittent, non-damaging, interference during
the lighting sequence with a TV plugged into the same
circuit. It is recommended that the replace and TV use
different circuits to mitigate the interference potential.
If interference is occurring on the same circuit, the use
of surge protectors may help alleviate the interference.