Installation Sheet
31
Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/19
Figure 4.18
Top Vent - Vertical Termination
Venting with 2 elbows
ECHEL36IN-C, ECHEL48IN-C, ECHEL60IN-C
ECHEL36STIN-C, ECHEL48STIN-C
V
1
+ V
2
Minimum H
Maximum
1-1/2 ft. 457 mm 4 ft. 1.2 m
2-1/2 ft. 762 mm 9 ft. 2.7 m
3-1/2 ft. 1.1 m 12 ft. 3.6 m
5 ft. 1.5 m 15 ft. 4.5 m
V
1
+ H
1
+ V
2
= 63 ft. (19.2 m) Maximum
H
Total
= 23 ft. (7.1 m) Maximum
ECHEL72IN-C
V
1
+ V
2
Minimum H
Maximum
2-1/2 ft. 762 mm 4 ft. 1.2 m
3-1/2 ft. 1.1 m 9 ft. 2.7 m
4-1/2 ft. 1.4 m 12 ft. 3.6 m
6 ft. 1.8 m 15 ft. 4.5 m
V
1
+ H
1
+ V
2
= 63 ft. (19.2 m) Maximum
H
Total
= 23 ft. (7.1 m) Maximum
Note: Use DVP Series
components only.
H
1
V
2
V
1
WARNING! Risk of Fire!
DO NOT attach elbow directly to the appliance.
• The ECHEL36IN-C/ECHEL36STIN-C, ECHEL48IN-C/ECHEL48STIN-C and ECHEL60IN-C require a minimum of 18 inches
of vertical venting before attaching any elbow to the appliance.
• The ECHEL72IN-C requires a minimum of 30 inches of vertical venting before attaching any elbow to the appliance.