Installation Sheet
27
Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/19
Figure 4.12
Top Vent - Horizontal Termination
Venting with 2 elbows
Note: Use DVP Series
components only.
ECHEL36IN-C, ECHEL48IN-C, ECHEL60IN-C
V
1
Minimum H
1
+ H
2
Maximum
1-1/2 ft. 457 mm 1-1/2 ft. 457 mm
2-1/2 ft. 762 mm 6 ft. 1.8 m
3-1/2 ft. 1.1 m 9 ft. 2.7 m
5 ft. 1.5 m 12 ft. 3.7 m
6 ft. 1.8 m 15 ft. 4.6 m
7 ft. 2.1 m 18 ft. 5.5 m
8 ft. 2.4 m 21 ft. 6.4 m
9 ft. 2.7 m 24 ft. 7.3 m
V
1
+ H
1
+ H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 24 ft. (7.3 m) Maximum
ECHEL36STIN-C, ECHEL48STIN-C
V
1
Minimum H
1
+ H
2
Maximum
1-1/2 ft. 457 mm 3 ft. 914 mm
2-1/2 ft. 762 mm 6 ft. 1.8 m
3-1/2 ft. 1.1 m 9 ft. 2.7 m
5 ft. 1.5 m 12 ft. 3.7 m
6 ft. 1.8 m 15 ft. 4.6 m
7 ft. 2.1 m 18 ft. 5.5 m
8 ft. 2.4 m 21 ft. 6.4 m
9 ft. 2.7 m 24 ft. 7.3 m
V
1
+ H
1
+H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 24 ft. (7.3 m) Maximum
ECHEL72IN-C
V
1
Minimum H
1
+ H
2
Maximum
2-1/2 ft. 762 mm 1-1/2 ft. 457 mm
3-1/2 ft. 1.1 m 6 ft. 1.8 m
4-1/2 ft. 1.4 m 9 ft. 2.7 m
6 ft. 1.8 m 12 ft. 3.7 m
7 ft. 2.1 m 15 ft. 4.6 m
8 ft. 2.4 m 18 ft. 5.5 m
9 ft. 2.7 m 21 ft. 6.4 m
10 ft. 3.0 m 24 ft. 7.3 m
V
1
+ H
1
+H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 24 ft. (7.3 m) Maximum
INSTALLED
HORIZONTALLY
H
2
H
1
V
1
WARNING! Risk of Fire!
DO NOT attach elbow directly to the appliance.
• The ECHEL36IN-C/ECHEL36STIN-C, ECHEL48IN-C/ECHEL48STIN-C and ECHEL60IN-C require a minimum of 18 inches
of vertical venting before attaching any elbow to the appliance.
• The ECHEL72IN-C requires a minimum of 30 inches of vertical venting before attaching any elbow to the appliance.