Installation Sheet

Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/1918
Figure 3.9 Clearances to Combustibles-ECHEL36STIN-C, ECHEL48STIN-C
MINIMUM FRAMING DIMENSIONS*
A B C D E F G H I J
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Sides of
Appliance
Front or
Rear of
Appliance
Clearance
to Ceiling
ECHEL36STIN-C
in.
10 42 17 48-1/4 31 0 0 1 48 55-1/2
mm
254 1067 432 1226 787 0 0 25 1219 1410
ECHEL48STIN-C
in.
10 42 17 60-1/4 31 0 0 1 48 55-1/2
mm
254 1067 432 1530 787 0 0 25 1219 1410
C
A
B
D
HEADER
DEPTH**
HEADER
DEPTH**
APPLIANCE MAY BE
INSTALLED OFF OF FLOOR***
* = Adjust framing dimensions for interior sheathing (such as sheetrock)
**= Header depth not to exceed 3-1/2 inches.
***= If appliance is installed off of oor, maintain required clearances to combustibles.
Construct platform in accordance with local building codes.
F
G
H
E
I
J
E=MEASUREMENT FROM TOP
OF FIREPLACE OPENING
TO CEILING
J=MEASUREMENT FROM
BOTTOM OF FIREPLACE
TO CEILING
NOTE: E & J dimensions will change if
Passive Heat option is installed. Reference the instructions
included with the Passive Heat Kit for dimensions.