Installation Sheet

17
Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/19
B
D
A
HEADER
DEPTH**
C
APPLIANCE MAY BE INSTALLED OFF OF FLOOR***
Figure 3.8 Clearances to Combustibles-ECHEL36IN-C, ECHEL48IN-C, ECHEL60IN-C, ECHEL72IN-C
MINIMUM FRAMING DIMENSIONS*
ECHEL48IN-C
A B C D E F G H I J K
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Clearance
to Ceiling
Inches
10 42 18-1/4 60-1/4 31 0 0 1 1 48 55-1/2
Millimeters
254 1067 464 1530 787 0 0 25 25 1219 1410
MINIMUM FRAMING DIMENSIONS*
ECHEL36IN-C
A B C D E F G H I J K
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Clearance
to Ceiling
Inches
10 42 18-1/4 48-1/4 31 0 0 1 1 48 55-1/2
Millimeters
254 1067 464 1226 787 0 0 25 25 1219 1410
MINIMUM FRAMING DIMENSIONS*
ECHEL60IN-C
A B C D E F G H I J K
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Clearance
to Ceiling
Inches
10 48 18-1/4 72-1/4 31 0 0 1 1 48 55-1/2
Millimeters
254 1219 464 1835 787 0 0 25 25 1219 1410
MINIMUM FRAMING DIMENSIONS*
ECHEL72IN-C
A B C D E F G H I J K
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Clearance
to Ceiling
Inches
10 48 18-1/4 84-1/4 31 0 0 1 1 48 55-1/2
Millimeters
254 1219 464 2140 787 0 0 25 25 1219 1410
* = Adjust framing dimensions for interior sheathing (such as sheetrock)
**= Header depth not to exceed 3-1/2 inches.
***= If appliance is installed off of oor, maintain required clearances to combustibles.
Construct platform in accordance with local building codes
F
G
J
I
E
H
K
NOTE: E & K dimensions will change if
Passive Heat option is installed. Reference the instructions
included with the Passive Heat Kit for dimensions.