Installation Sheet

15
Majestic • ECHEL36IN-C/STIN-C, ECHEL48IN-C/STIN-C, ECHEL60IN-C, ECHEL72IN-C Installation Manual • 2608-980 Rev. C • 8/19
B. Appliance Location and Clearances to
Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls and allow suf-
cient clearance for heat management systems venting.
See Figure 3.6 and Figure 3.7.
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be located
out of trafc and away from furniture and draperies.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.6 Appliance Locations: ECHELON-C Single-Sided Models
Model A B C D E F G H
ECHEL36IN-C
Inches 62-1/2 48-1/4 88-1/8
See
Section
10, Figure
10.17 and
10.18.
24-1/2 18-3/4 1 50
Millimeters 1588 1226 2238 622 476 25 1270
ECHEL48IN-C
Inches 70-3/4 60-1/4 100-3/8 28-1/2 18-3/4 1 62
Millimeters 1797 1530 2550 724 476 25 1575
ECHEL60IN-C
Inches 79-1/2 72-1/4 112-3/8 31-3/4 18-3/4 1 74
Millimeters 2019 1835 2854 807 476 25 1880
ECHEL72IN-C
Inches 88 84-1/4 124-3/8 35-1/4 18-3/4 1 86
Millimeters 2235 2140 3159 895 476 25 2184
B
C
A
B
G
F
E
H
G
D
Refer to Section 10 for hearth, mantel and
wall projection information.
If a Heat Management System will be
installed, refer to Section 6.B for information.
B
18 in. (457 mm) required when Passive Heat Side
Discharge Kit is installed. Refer to the Passive
Heat kit instructions for more information.