Installation Instruction

20302381
13
Designer Series Direct Vent Gas Fireplace



 The combustible area above the facing must
not protrude more than 1/2" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
Vermont Castings Group Model BPWC500
Mantel is designed to comply with all mantel temperature
requirements.

     


      
     
      

   
   


FP2817
mantel clearances
16”
12”
10”
12”
6”
256O




FP2817
Top of Fireplace
Opening




45°
1”
4”
5”
6”
3”
FP2818
mantel leg clearance
Figure 10 -
Mantel Clearance
Stud
Combustible
Material Area
FP2818

Spacer
Side of Fireplace
Opening
72”
(1829 mm)
Min.
Ceiling
6”
(152 mm)
Min.
FP2832
ceiling wall clearance
Figure 9 -
Ceiling and Side Wall Clearances
FP2544
12"
(305 mm)
Max. Depth
16"
(406 mm)
Min.
Combustible Mantel